{"id":16517,"date":"2017-03-18T12:20:14","date_gmt":"2017-03-18T11:20:14","guid":{"rendered":"\/en\/departments\/department-of-metrology-and-modelling-of-agrophysical-processes\/laboratory-of-evaluation-treatment-and-utilization-of-post-fermentation-sludge\/aparatura\/"},"modified":"2017-05-08T11:22:58","modified_gmt":"2017-05-08T09:22:58","slug":"equipment","status":"publish","type":"page","link":"https:\/\/www.ipan.lublin.pl\/en\/departments\/department-of-metrology-and-modelling-of-agrophysical-processes\/laboratory-of-evaluation-treatment-and-utilization-of-post-fermentation-sludge\/equipment\/","title":{"rendered":"Equipment"},"content":{"rendered":"<div class=\"wpb-content-wrapper\" id=\"wpb-content-root\"><p>[vc_row css_animation=&#8221;&#8221; row_type=&#8221;row&#8221; use_row_as_full_screen_section=&#8221;no&#8221; type=&#8221;full_width&#8221; angled_section=&#8221;no&#8221; text_align=&#8221;left&#8221; background_image_as_pattern=&#8221;without_pattern&#8221;][vc_column][vc_column_text]<\/p>\n<h3><img loading=\"lazy\" decoding=\"async\" class=\"alignright size-medium wp-image-15261\" src=\"\/wp-content\/uploads\/2017\/03\/p3-300x233.jpg\" alt=\"\" width=\"300\" height=\"233\" srcset=\"https:\/\/www.ipan.lublin.pl\/wp-content\/uploads\/2017\/03\/p3-300x233.jpg 300w, https:\/\/www.ipan.lublin.pl\/wp-content\/uploads\/2017\/03\/p3.jpg 326w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/h3>\n<h3>X-ray microtomograph<\/h3>\n<p>&nbsp;<\/p>\n<p class=\"ListParagraph\"><strong>Specifications:<\/strong><\/p>\n<ul>\n<li>X-ray source max.: 180 kV, 15W<\/li>\n<li>Max. scanning resolution: &lt;0.5 \u00b5m<\/li>\n<li>Digital detector resolution: 5 Mpx<\/li>\n<li>Maximum size of scanned object: diameter \u2013 120 mm, heigh \u2013 150 mm<\/li>\n<li>Maximum mass of scanned object: 2 kg<\/li>\n<li>Option for samples cooling and stressing<\/li>\n<\/ul>\n<p>[\/vc_column_text][vc_separator type=&#8221;normal&#8221; color=&#8221;#e6e6e6&#8243; thickness=&#8221;1&#8243; down=&#8221;30&#8243;][vc_column_text]<\/p>\n<h3><img loading=\"lazy\" decoding=\"async\" class=\"alignright size-medium wp-image-15230\" src=\"\/wp-content\/uploads\/2017\/03\/IMG_4915-200x300.jpg\" alt=\"\" width=\"200\" height=\"300\" srcset=\"https:\/\/www.ipan.lublin.pl\/wp-content\/uploads\/2017\/03\/IMG_4915-200x300.jpg 200w, https:\/\/www.ipan.lublin.pl\/wp-content\/uploads\/2017\/03\/IMG_4915.jpg 400w\" sizes=\"auto, (max-width: 200px) 100vw, 200px\" \/><\/h3>\n<h3>Set for water hysteresis effect determination<\/h3>\n<p>&nbsp;<\/p>\n<p><strong>Specifications:<\/strong><\/p>\n<ul>\n<li>Set for ceramic plates for measuring range from 0 to 2 Bars<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>[\/vc_column_text][vc_separator type=&#8221;normal&#8221; color=&#8221;#e6e6e6&#8243; thickness=&#8221;1&#8243; down=&#8221;30&#8243;][vc_column_text]<\/p>\n<h3><img loading=\"lazy\" decoding=\"async\" class=\"alignright size-medium wp-image-15263\" src=\"\/wp-content\/uploads\/2017\/03\/p2-300x196.jpg\" alt=\"\" width=\"300\" height=\"196\" srcset=\"https:\/\/www.ipan.lublin.pl\/wp-content\/uploads\/2017\/03\/p2-300x196.jpg 300w, https:\/\/www.ipan.lublin.pl\/wp-content\/uploads\/2017\/03\/p2-768x502.jpg 768w, https:\/\/www.ipan.lublin.pl\/wp-content\/uploads\/2017\/03\/p2-400x260.jpg 400w, https:\/\/www.ipan.lublin.pl\/wp-content\/uploads\/2017\/03\/p2-700x458.jpg 700w, https:\/\/www.ipan.lublin.pl\/wp-content\/uploads\/2017\/03\/p2.jpg 918w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/h3>\n<h3>Set for heat properties determinations KD2 Pro<\/h3>\n<p>&nbsp;<\/p>\n<p><strong>Specifications:<\/strong><\/p>\n<ul>\n<li>heat conductivity from 0,02 to 4 Wm<sup>-1<\/sup>C<sup>-1<\/sup><\/li>\n<li>heat diffusivity from 0,1 to 1,0 mm<sup>2<\/sup>s<sup>-1<\/sup><\/li>\n<li>heat resistancefrom 0,25 to 50 mCW<sup>-1<\/sup><\/li>\n<li>specific heat from 0,5 to 4 MJm<sup>-3<\/sup>C<sup>-1<\/sup><\/li>\n<\/ul>\n<p>[\/vc_column_text][vc_separator type=&#8221;normal&#8221; color=&#8221;#e6e6e6&#8243; thickness=&#8221;1&#8243; down=&#8221;30&#8243;][vc_column_text]<\/p>\n<h3><img loading=\"lazy\" decoding=\"async\" class=\"alignright size-medium wp-image-15264\" src=\"\/wp-content\/uploads\/2017\/03\/p1-201x300.jpg\" alt=\"\" width=\"201\" height=\"300\" srcset=\"https:\/\/www.ipan.lublin.pl\/wp-content\/uploads\/2017\/03\/p1-201x300.jpg 201w, https:\/\/www.ipan.lublin.pl\/wp-content\/uploads\/2017\/03\/p1.jpg 401w\" sizes=\"auto, (max-width: 201px) 100vw, 201px\" \/><\/h3>\n<h3>Set to collect soil samples<\/h3>\n<p>&nbsp;<\/p>\n<p><strong>Specifications:<\/strong><\/p>\n<ul>\n<li>Sample collection diameter: 53, 60 i 84mm<\/li>\n<li>Maximal depth of sample collection: 2,5m<\/li>\n<li>Suitcase for 24 soil samples<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>[\/vc_column_text][vc_separator type=&#8221;normal&#8221; color=&#8221;#e6e6e6&#8243; thickness=&#8221;1&#8243; down=&#8221;30&#8243;][vc_column_text]<\/p>\n<h3><img loading=\"lazy\" decoding=\"async\" class=\"alignright size-medium wp-image-15265\" src=\"\/wp-content\/uploads\/2017\/03\/p4-249x300.jpg\" alt=\"\" width=\"249\" height=\"300\" srcset=\"https:\/\/www.ipan.lublin.pl\/wp-content\/uploads\/2017\/03\/p4-249x300.jpg 249w, https:\/\/www.ipan.lublin.pl\/wp-content\/uploads\/2017\/03\/p4.jpg 497w\" sizes=\"auto, (max-width: 249px) 100vw, 249px\" \/><\/h3>\n<h3>Set for heat properties determinations FTN01<\/h3>\n<p>&nbsp;<\/p>\n<p><strong>Specifications:<\/strong><\/p>\n<ul>\n<li>heat conductivity from 0,1 to 6 Wm<sup>-1<\/sup>C<sup>-1<\/sup><\/li>\n<li>lenght of probe 1,5m<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row css_animation=&#8221;&#8221; row_type=&#8221;row&#8221; use_row_as_full_screen_section=&#8221;no&#8221; type=&#8221;full_width&#8221; angled_section=&#8221;no&#8221; text_align=&#8221;left&#8221; background_image_as_pattern=&#8221;without_pattern&#8221;][vc_column][vc_column_text] X-ray microtomograph &nbsp; Specifications: X-ray source max.: 180 kV, 15W Max. scanning&#8230;<\/p>\n","protected":false},"author":7,"featured_media":6082,"parent":16218,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"iapan_zaklad_4.php","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-16517","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.ipan.lublin.pl\/en\/wp-json\/wp\/v2\/pages\/16517","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ipan.lublin.pl\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.ipan.lublin.pl\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.ipan.lublin.pl\/en\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ipan.lublin.pl\/en\/wp-json\/wp\/v2\/comments?post=16517"}],"version-history":[{"count":0,"href":"https:\/\/www.ipan.lublin.pl\/en\/wp-json\/wp\/v2\/pages\/16517\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.ipan.lublin.pl\/en\/wp-json\/wp\/v2\/pages\/16218"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ipan.lublin.pl\/en\/wp-json\/wp\/v2\/media\/6082"}],"wp:attachment":[{"href":"https:\/\/www.ipan.lublin.pl\/en\/wp-json\/wp\/v2\/media?parent=16517"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}